TY-SHARK-3KRL
Model: TY-SHARK-3KRL
working way: Rack Mount HF Online UPS
Product Introduction: Special Design for Small & Medium Enterprise Server Usage, 2U Rack Mount Installation, Online Double Conversion Design, DSP Digital Technology, Pure Sine Wave, High Performance with Better Outlook, the combination of Conventional Product with High End Technology
working way: Rack Mount HF Online UPS
Product Introduction: Special Design for Small & Medium Enterprise Server Usage, 2U Rack Mount Installation, Online Double Conversion Design, DSP Digital Technology, Pure Sine Wave, High Performance with Better Outlook, the combination of Conventional Product with High End Technology
Features:
1, DSP Digital Controller ensure the better quality and high performance of the User Experience
2, Load Power Factor is 1.0 which will have a better load capability on connecting devices
3, PFC (Power Factor Correction) help improve the Input Power Factor up to 0.98
4, Wide Input Voltage and Frequency Range suitable for the Remote are with Harsh Power Grid.
5. Able to feed to the Generator
6. Zero Conversion to ensure the safety and reliablity of the load
Technical Specifications:
Capacity | 2KVA/2KW | |
Input | Nominal Voltage | 100/110/115/120 Vac |
Voltage Range | 55-150 Vac at 50% load : 80-150 Vac at 100% load | |
Frequency | 40-70Hz | |
Power Factor | >0.99@nominal voltage (100% load) | |
THDI | <5%@nominal input voltage | |
Output | Voltage Range | 100/110/115/120 Vac |
Voltage Regulation | ±1% | |
Frecuency Range | 50Hz/60Hz±0.1Hz | |
Current Crest Ratio | 3:1 | |
Harmonic Distortion | 2% THD (Linear load) 4% THD(Non-linear load) | |
Transfer Time | 0ms | |
Wave Form | Pure Sinewave | |
Efficiency | AC Mode | 91% |
ECO Mode | 96% | |
Batterry Mode | 90% | |
Battery | Battery Voltage | 48 VDC |
Baterry No | External | |
Typical Recharge Time | 3 hours recover to 95% capacity | |
Charging Current | 8A max | |
Charging Voltage | 54.8 VDC ± 1% | |
Indicators | LCD Panel | UPS Status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
Alarm | Battery Mode | Sounding every 5 seconds |
LowBattery | Sounding every 2 seconds | |
Overload | Sounding every second | |
Fault | Continously sounding | |
Enviroment | Humidity | 20-90% RH @ -5 - 74℃ (non-condensing) |
Noise Level | Less than 50dBA @ 1 Meter | |
Management | RS232/USB | Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC |
Optional SNMP | Power management form SNMP manager and web browser | |
Physical | Dimension D*W*H (mm) | 420*438*88 |
Net Weight (kgs) | 9.9 | |
Special Features | true online double-conversion technology | |
Wide input voltae range and sable power supply extends battery lifetime | ||
DSP technology | ||
Advanced PFC technology, input PF>99% | ||
Cold start | ||
Automatic battery charging on/off mode | ||
Lighting and surege protection | ||
LCD/LED display | ||
Smart RS232 port with monitoring software | ||
Smart slot for some critical applications |